VFD Drive | Energy Efficient | Quiet Operation

Electric Drive Pump Unit: Clean, Efficient, Precise Pumping

An electric drive pump unit uses an electric motor with variable frequency drive (VFD) to power the high-pressure pump. It plugs into your power supply —no fuel, no exhaust, no engine noise. Electric drive is the standard for permanent installations and environmentally sensitive locations.

Electric drive pump unit with VFD control

When to Choose Electric Drive

Electric drive pump units are the right choice when:

  • The installation site has reliable grid power or a dedicated generator supply
  • The pump will run for long hours continuously (24/7 production service)
  • Noise and emissions regulations restrict diesel engine operation
  • You want precise speed and pressure control for sensitive operations
  • The pump is permanently installed and won't be moved frequently

If you need a mobile pump for remote locations with no power, diesel drive is the practical choice. For permanent or semi-permanent installations with power available, electric drive saves money over time.

Advantages of VFD Electric Drive

Energy Efficiency

Electric motors convert electricity to mechanical energy at 90%+ efficiency. Diesel engines run at 30-40%. Over thousands of operating hours, the electricity savings are substantial. For a pump that runs 2000+ hours per year, electric drive pays back the premium within 2-3 years.

Precise Control

VFD allows infinite speed control from 0 to maximum. You can precisely set flow rate and pressure —critical for cementing, well testing and injection operations. The driller can make fine adjustments without changing plunger sizes or engine RPM.

Quiet & Clean

Electric motors are much quieter than diesel engines (65-75 dB vs 95-105 dB). No exhaust emissions. This is increasingly important as environmental regulations tighten. On offshore platforms, in populated areas, or near sensitive ecosystems, electric drive may be required.

Lower Maintenance

Electric motors have far fewer moving parts than diesel engines. No oil changes, no fuel filters, no radiator service, no exhaust system maintenance. The motor itself needs minimal maintenance —just periodic bearing lubrication and insulation testing.

Typical Specifications

Parameter Typical Range
Motor type AC induction motor, TEFC enclosure
Motor power 100 - 1500 kW (134 - 2012 HP)
VFD type IGBT-based, regenerative braking option
Power supply 380V / 480V / 690V, 3-phase, 50/60 Hz
Working pressure 35 - 105 MPa
Flow rate 100 - 2500 L/min

Frequently Asked Questions

What power supply do I need for an electric pump?

Typically 3-phase 380V, 480V or 690V, 50 or 60 Hz. The exact requirement depends on motor size. A 200 kW motor needs about 400-500 kVA supply. A 1000 kW motor needs about 2000 kVA. Most oilfield substations and generators can handle this load. We can specify the exact power requirement based on your pump size.

Can I convert my diesel pump to electric drive?

Yes. You can replace the diesel engine with an electric motor and add a VFD control panel. The existing pump, transmission and base can stay. This is more cost-effective than buying a new pump. We offer retrofitting services —we can convert your existing diesel pump to electric drive at our facility or on-site.

How much money does electric drive save?

Over 2000 operating hours per year, electric drive typically saves 30-40% on energy costs compared to diesel. A typical 300 HP diesel pump uses about 50 liters of diesel per hour —that's 100,000 liters per year. At $0.80/liter, that's $80,000 per year in fuel. Electric drive cuts this by 30-40%, saving $24,000-32,000 per year. The VFD premium pays back in 2-3 years.

Need an Electric Drive Pump Unit?

Tell us your required pressure, flow rate and available power supply. Our engineering team will recommend the right pump configuration and provide a quote within 48 hours.